Abloy Package 2
< Abloy Kits

Package 2

Abloy Package 2

  • Standard Door Read in/Read out

Description

Read in, read out

1. EL561 solenoid lock

2. CY327 double cylinder - DIN Europrofile

3. EA280 concealed door loop

4. 60-0319-SSS handle set

5. DC240 door closer (optional)

6. 3-19/042 PZ+PZ-SSS (alternative)

Wood or metal door applications with handle operation, both handles controlled and

activated on signal from access control system. Key override at all times from both sides.

Technical Specification:

Operating voltage: 12 V DC to 24 V DC stabilised (+15%-10%).

Current draw: 12 V DC 350 mA max 24 V DC 250 mA max.

Backsets available: Standard 65 mm, 55 mm, 60 mm.

Monitoring: RQE on inside handle, bolt position, door position, cylinder operation.

Standards:

EN1634-1

EN61000-6-1

EN1303 (cylinder)

EN14846